" Gusset Column Cap " & " Weld Conn2 " & " Weld Conn1 " & " Brace Connection To Gusset Wide Flange Claw "
The gusset plate for a web-horizontal wide flange vertical brace to a column & base plate (shown) or to a column & cap plate (not shown) is designed per " Gusset Column Cap " locks. When ' Web claw angles ' is the " Connection arrangement ," the brace-gusset connection is designed per " Brace Connection To Gusset Wide Flange Claw " locks. Shop welding of the gusset to the column and column plate is done per " Weld Conn2 " and " Weld Conn1 " locks. If the column is perfectly vertical, the gusset's " Width " is measured horizontally and its " Length " is measured vertically. |
|
|||
" Gusset Column Cap "
(gusset plate dimensions and location) |
" Gusset Column Cap "
(cuts to the gusset plate) |
||
" Brace Conn To Gusset Wide Flange Claw " (angle to gusset connection) |
" Brace Conn To Gusset Wide Flange Claw " (angle to brace connection) |
||
" Weld Conn 2 " and " Weld Conn1 " (shop weld for the gusset plate to the supporting column and column plate) |
|
user defined | vertical brace review | top
Connection design locks :
Locks not on the drawing are marked ( not depicted ). |
Gusset Column Cap
( web-horizontal wide flange vertical brace, claw angles, to column & base/cap plate )
Gusset plate dimensions and location
Plate thickness ( not depicted ):
Connection cut width ( cut width ):
Connection cut length ( cut length ):
Clip column side cut width ( cs cut width ):
Clip column side cut length ( cs cut length ):
Clip beam side cut width ( bs cut width ):
Clip beam side cut length ( bs cut length):
Slope clip cut width ( slope cut width ):
user defined | vertical brace review | top
Brace Connection To Gusset Wide Flange Claw
( web-horizontal wide flange, claw angles, to column & base/cap plate )
Claw angle dimensions and location
Section size ( not depicted ):
Gage leg ( not depicted ):
Angle to gusset connection (field bolted)
Bolt diameter ( not depicted ):
Distance to 1st hole along brace ( to 1st hole ):
Hole spacing along brace ( sp ):
Angle to brace connection (shop bolted)
Bolt diameter ( not depicted ):
Distance to 1st hole along brace ( to 1st hole ):
Hole spacing along brace ( S ):
Edge distance along brace ( not depicted ):
user defined | vertical brace review | top
Weld Conn2
( web-horizontal wide flange, claw angles, to column & base/cap plate )
Shop weld, gusset to the supporting column
Weld size ( weld2 ):
user defined | vertical brace review | top
Weld Conn1
( wide flange, paddle plates, to a column & user base/cap plate )
Shop weld, gusset to the column plate
Weld size ( weld1 ):
For an auto base/cap plate: When the " Input connection type " for the column is ' Auto base/cap plate ', the " Weld size " connection design lock found on the Vertical Brace Review window under " Cap Plate " sets the weld size for the gusset to auto base/cap plate.