" Gusset One Member " & " Weld Conn2 " connection design locks
A gusset plate for an HSS, pipe or tube vertical brace to a column is designed per " Gusset One Member " locks regardless of the " Pipe/tube end-fitting ." For ' Welded ', 0 or 1 or 2 holes are centered on the workline. The gusset plate shop attaches to the column per " Weld Conn2 " or " NS/FS Clip Conn2 " locks. The " Plate length " runs parallel with the workline of the column. |
|
|||
" Gusset One Member "
(gusset plate dimensions and location) |
" Gusset One Member "
(acute side and obtuse side cuts) |
||
" Weld Conn 2 "
(" Gusset to supporting member " = ' Welded ') |
|
user defined | vertical brace review | top
Connection design locks :
Locks not on the drawing are marked ( not depicted ). |
Gusset One Member
( HSS vertical brace to a column )
Gusset plate dimensions and location
Plate thickness ( not depicted ):
Connection cut width ( cut width ):
Connection cut length ( cut length ):
Acute side clip cut width ( acute side cut width ):
Acute side clip cut length ( acute cut length ):
Obtuse side clip cut width ( obtuse cut width ):
user defined | vertical brace review | top
Weld Conn2
( HSS vertical brace to a column )
Shop weld, gusset plate to the supporting column
Weld size ( weld ):
" Weld Conn2 " locks become available when ' Welded ' is selected for " Gusset to supporting member " under " Connection specifications " on the Vertical Brace Review window.
" NS/FS Clip Conn2 " locks become available when ' Clip angle ' is selected for " Gusset to supporting member ."