The Welded Connection Settings window ( Fabricator Settings )
- These settings are read-only . They apply in a full-featured SDS2 program when the " Input connection type " on a vertical brace is ' Welded ' and the vertical brace is a ' Back to back ' double-angle to the stem of a W tee (or S tee) chord member.
Also see :
- Brace to supporting member (field clearance setup)
- Brace to brace (field clearance setup)
page 1 | contents | home > project settings > fabricator > standard fabricator connections > | classic
To open the Welded Connection Settings window :
Method 1 : Home > Project Settings > Fabricator > Standard Fabricator Connections > Welded Connection Settings .
page 1 | contents | home > project settings > fabricator > standard fabricator connections > | classic | top
Weld all around angle branch: or
. This applies when ' Automatic ' is selected for " Weld all around angle branch " on the Vertical Brace Review window or at Home > Project Settings > Job > User Defined Connections . The " Input connection type " on the Vertical Brace window can be ' Welded ' or ' User defined '.
|
|
When " Weld all around angle branch " is ' Automatic ' in a full-featured SDS2 program . . .
If this box is checked (
), connection design welds all three edges of the angle that contact the stem of the W tee (or S tee) chord member.
If the box is not checked (
), connection design welds only the top and bottom length edges of the angle, not its forward edge.
Connection weld size: Auto or a user-entered size . This applies to back-to-back double-angle vertical braces to a W tee (or S tee) chord member when ' Welded ' is the " Input connection type ."
Connection weld size: ![]() |
|
|
or | ||
Connection weld size: ![]() |
|
If the box for " Auto " is checked (
), connection design in a full-featured SDS2 program calculates the " Weld size " that is required.
If the box for " Auto " is not checked (
), the weld size has been entered by the user of a full-featured SDS2 program . Be aware that if a " Connection weld size " that is too large is entered, the connection will fail.
page 1 | contents | home > project settings > fabricator > standard fabricator connections > | classic | top