The AS 4100 Phi Factors window ( Job Settings )
Also see :
- Connection design method (must be set to ' AS 4100 ' for this window to apply)
- Connection design (phi factors are applied during)
contents | design settings | top
To open the AS 4100 Phi Factors window :
1 . On the " Design Settings " window, ' AS 4100 ' must be selected as the " Connection design method ."
2 . Press the " AS 4100 Phi Factors " button.
3 . The AS 4100 window opens.
contents | design settings | top
|| Tension || Combined Actions || |
|| Pin || Weld || Bolts || Other || Bending || Compression || |
Shear (9.5.1) : The default capacity factor for a pin in shear is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.5.1 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Bearing (9.5.2) : The default capacity factor for a pin in bearing is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.5.2 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Bending (9.5.3) : The default capacity factor for a pin in bending is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.5.3 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Ply in bearing (9.5.4) : The default capacity factor for a ply subject to a design bearing force due to a pin in shear is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.5.4 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
contents | design settings | top
|| Tension || Combined Actions || |
|| Pin || Weld || Bolts || Other || Bending || Compression || |
Complete penetration butt weld (9.7.2.7) : The default capacity factor for a complete penetration butt weld is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.7.2.7 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Longitudinal fillet weld in RHS (t<3 mm) (9.7.3.10) : The default capacity factor is 0.7 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.7.3.10 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Other fillet weld and incomplete penetration butt weld (9.7.3.10.2) : The default capacity factor is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.7.3.10.2 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Plug or slot weld (9.7.4) : The default capacity factor is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.7.4 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Weld group (9.8) : The default capacity factor for a fillet weld group subject to in-plane loading or out-of-plane loading is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.8 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
contents | design settings | top
|| Tension || Combined Actions || |
|| Pin || Weld || Bolts || Other || Bending || Compression || |
Shear (9.3.2.1) : The default capacity factor for a bolt in shear is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.3.2.1 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Tension (9.3.2.2) : The default capacity factor for a bolt in tension is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.3.2.2 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Tension and shear on bolt (9.3.2.3) : The default capacity factor for a bolt subject to combined tension and shear is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.3.2.3 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Ply in bearing (9.3.2.4) : The default capacity factor for a ply subject to a design bearing force due to a bolt in shear is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.3.2.4 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Friction-type bolts (9.3.3) : The default capacity factor is 0.7 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.3.3 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Bolt group (9.4) : The default capacity factor for a bolt group subject to in-plane loading or out-of-plane loading or combinations thereof is 0.8 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.4 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
contents | design settings | top
|| Tension || Combined Actions || |
|| Pin || Weld || Bolts || Other || Bending || Compression || |
Component other than a bolt, pin, or weld (9.1.9) : The default capacity factor for connection components other than connectors is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 9.1.9 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
contents | design settings | top
|| Tension || Combined Actions || |
|| Pin || Weld || Bolts || Other || Bending || Compression || |
Full lateral support (5.2) : The default capacity factor is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 5.2 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Segment without full lateral support (5.6) : The default capacity factor for segments without full lateral restraint is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 5.6 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Web in shear (5.11) : The default capacity factor for a web subject to a design shear force is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 5.11 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Web in bearing (5.13) : The default capacity factor for compressive bearing action on the edge of a web is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 5.13 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Stiffener (5.14) : The default capacity factor for the design of load bearing stiffeners is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 5.14 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
contents | design settings | top
|| Tension || Combined Actions || |
|| Pin || Weld || Bolts || Other || Bending || Compression || |
Section capacity (6.2) : The default capacity factor is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 6.2 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Member capacity (6.3) : The default capacity factor is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 6.3 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
contents | design settings | top
|| Pin || Weld || Bolts || Other || Bending || Compression || |
|| Tension || Combined Actions || |
Axial tension (7.1) : The default capacity factor for a member subject to a design axial tension force is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 7.1 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
contents | design settings | top
|| Pin || Weld || Bolts || Other || Bending || Compression || |
|| Tension || Combined Actions || |
Section capacity (8.3) : The default capacity factor is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 8.3 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
Member capacity (8.4) : The default capacity factor is 0.9 .
For information on how this capacity factor is used by a full-featured SDS2 program , refer to section 8.4 of the Australian Standard for Steel Structures, AS4100 -- 1998 .
contents | design settings | top
"OK" (or the Enter key) closes the AS 4100 Phi Factors window (this window).