Gusset One Member " & "
HB Conn2 " connection design locks
An HSS, pipe or tube horizontal brace to the top flange of a beam can be field attached to its gusset plate (" ![]() ![]() |
|
|||
" ![]() (gusset plate dimensions and location) ![]() |
" ![]() (acute side and obtuse side cuts) ![]() |
||
" ![]() (shop weld, gusset to beam flange) ![]() |
|
Connection design locks :
Locks not on the drawings are marked ( not depicted ). |
Gusset One Member Square
(HSS, pipe or tube horizontal brace to a beam's top flange)
Plate thickness ( not depicted ):
Connection cut width ( cut width ):
Connection cut length ( cut lngth ):
Acute side clip cut width ( acute side cut width ):
Acute side clip cut length ( acute side cut length ):
Obtuse side clip cut width ( obtuse cut width ):
user defined | horizontal brace review | top
HB Conn2
(gusset-to-beam shop weld)
Weld size ( weld ):