" Gusset One Member " & " Weld Conn2 " connection design locks
An angle, W tee or channel vertical brace field bolts directly to a gusset plate (" Gusset One Member ") that shop attaches to a column. The gusset's corner is clipped pependicular to the brace's workline due to " Clip end operation " being set to ' Yes ' or, possibly, to ' Automatic '. Gusset-to-column shop welding is per choices made to " Weld Conn2 ." If the column is perfectly vertical, the gusset's " Width " is measured horizontally. |
|
|||
" Gusset One Member "
(gusset plate dimensions and location) |
" Gusset One Member "
(acute side and obtuse side cuts) |
||
" Weld Conn 2 "
(" Gusset to supporting member " = ' Welded ') |
|
user defined | vertical brace review
Connection design locks :
Locks not on the drawing are marked ( not depicted ). |
Gusset One Member
( angle, W tee or channel vertical brace to a column )
Gusset plate dimensions and location
Plate thickness ( not depicted ):
Connection cut width ( cut width ):
Connection cut length ( cut length ):
Acute side clip cut width ( acute side cut width ):
Acute side clip cut length ( acute cut length ):
Obtuse side clip cut width ( obtuse cut width ):
user defined | vertical brace edit | top
Weld Conn2
( angle, W tee or channel vertical brace to a column )
Shop weld, gusset plate to the supporting column
Weld size ( weld ):
You get a weld (" Weld Conn2 ") when ' Welded ' is selected for " Gusset to supporting member " under " Connection specifications " on the Vertical Brace Review window.
You get a clip angle ( NS/FS Clip Conn2 ") when ' Clip angle ' is selected for " Gusset to supporting member ."