Gusset 2 Point " & "
Weld Conn2 " connection design locks
Angle, W tee or channel vertical braces field bolt directly to a shared gusset plate (" ![]() ![]() ![]() |
|
|||||
" ![]() (gusset plate dimensions and location) ![]() |
" ![]() (" Gusset to supporting member " = ' Welded ') ![]() |
||||
|
user defined | vertical brace review | top
Connection design locks :
Locks not on the drawing are marked ( not depicted ). |
Gusset 2 Point
( angle, W tee or channel vertical braces, 2- or 3-point, to a column )
Shared gusset plate dimensions and location
Plate thickness ( not depicted ):
Left Brace [ member number ] (the lower brace is the left brace if the column is perfectly vertical)
Right Brace [ member number ] (the upper brace is the right brace if the column is perfectly vertical)
Refx ( refx right ):
Connection cut width:
Connection cut length:
user defined | vertical brace review | top
Weld Conn2
( angle, W tee or channel vertical braces, 2- or 3-point, to a column )
Shop weld, gusset plate to the supporting column
Weld size ( weld ):
"
Weld Conn2 " locks are available when ' Welded ' is selected for " Gusset to supporting member " under "
Connection specifications " on the Vertical Brace Review window.
"
NS/FS Clip Conn2 " locks are available when ' Clip angle ' is selected for " Gusset to supporting member ."