Gusset One Member " & "
Weld Conn2 " connection design locks
An angle, W tee or channel vertical brace field bolts directly to a gusset plate (" ![]() ![]() |
|
|||
" ![]() ( gusset plate dimensions and location ) ![]() |
" ![]() ( acute side and obtuse side cuts ) ![]() |
||
" ![]() ( " Gusset to supporting member " = ' Welded ' ) ![]() |
|
user defined | vertical brace review
Connection design locks :
Locks not on the drawing are marked ( not depicted ). |
Gusset One Member
( angle, W tee or channel vertical brace to a column )
Gusset plate dimensions and location
Plate thickness ( not depicted ):
Connection cut width ( cut width ):
Connection cut length ( cut length ):
Acute side clip cut width ( acute side cut width ):
Acute side clip cut length ( acute cut length ):
Obtuse side clip cut width ( obtuse cut width ):
user defined | vertical brace edit | top
Weld Conn2
( angle, W tee or channel vertical brace to a column )
Shop weld, gusset plate to the supporting column
Weld size ( weld ):
You get a weld ("
Weld Conn2 ") when ' Welded ' is selected for " Gusset to supporting member " under "
Connection specifications " on the Vertical Brace Review window.
You get a clip angle (
NS/FS Clip Conn2 ") when ' Clip angle ' is selected for " Gusset to supporting member ."