" Gusset One Member " connection design locks
The gusset of an angle, double-angle, W tee or wide flange horizontal brace to a beam's top flange is designed per " Gusset One Member " locks. The gusset shop welds to the flange. |
|
|||
" Gusset One Member "
(gusset plate dimensions and location) |
" Gusset One Member "
(acute side and obtuse side cuts) |
||
|
|
user defined | horizontal brace review | top
Connection design locks :
Locks not on the drawing are marked ( not depicted ). |
Gusset One Member Square
(L, WT, 2L or W horizontal brace to a beam's top flange)
Plate thickness ( not depicted ):
Connection cut width ( cut width ):
Connection cut length ( cut lngth ):
Acute side clip cut width ( acute side cut width ):
Acute side clip cut length ( acute side cut length ):
Obtuse side clip cut width ( obtuse cut width ):