NS/FS Clip Conn2 " connection design locks
" ![]() |
|
||||
"
|
"
|
|||
|
user defined | vertical brace review | top
Connection design locks :
Locks not called out or dimensioned on the drawing are marked ( not depicted ). |
NS/FS Clip Conn2
( vertical brace to a beam & column )
Clip angle
Section size ( not depicted ):
Long leg to ( not depicted ):
Connection to supported (gusset clip angle, NS or FS, leg welded or bolted to the gusset plate) :
When "
Connection specifications " > " Gusset to clip connection " is set to ' Welded ', you get a " Weld size " entry field, but no options for bolting:
Weld size ( weld ): The weld size used to shop weld the "
NS Clip Conn2 " or "
FS Clip Conn2 " clip angle to the gusset plate (see example ).
When " Gusset to clip connection " is set to ' Bolted ', you get the following " Connection to supported " options for shop bolting the brace to the gusset plate. " Connection to supported " settings can be different than the entries made to " Connection to supporting " fields.
Bolt diameter ( not depicted ):
diameter of leg-to gusset shop bolts ![]()
Rows:
Vertical to 1st hole:
Vertical hole spacing:
Top vertical edge distance:
Bottom vertical edge distance:
Connection to supporting (vbr to bm & col, gusset clip NS or FS, leg that shop bolts to the beam) :
Bolt diameter ( not depicted ):
diameter of shop bolts for the leg to the beam ![]()
![]()
Vertical to 1st hole ( vert to 1st ):
Vertical hole spacing ( spacing ): The entry made here can be one vertical spacing distance or variable hole spacing. See the video and table below.
VIDEO ![]()
Variable hole spacing can be typed to locked " Vertical hole spacing " fields found in leaves named " Shear Tab "; "
Bent Plate " "
End Plate " and "
NS/FS Clip ." (Recorded in SDS2 Detailing , v2016.)
Rows Spacing Result 5 3,5,3,3 4 spaces at 3", 5", 3" and 3" 5 3,5,2@3 4 spaces at 3", 5", 3" and 3" 5 3,5,3 4 spaces at 3", 5", 3" and 3"
(the last spacing -- 3 -- is repeated to fill the spaces that are required for the number of rows)5 3,5,3,3,2,3 End connection failure message (see below). End connection failure message: Variable row spacing specifies too many rows
Top vertical edge distance ( ed ):
user defined | vertical brace review | top
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.