AISC Verification Problem Example II.A-1A

Problem Statement

This document presents a comparative study between the published American Institute of Steel Construction (AISC) Design Examples Version 16.0 and the results generated by SDS2 version 2025.01 connection software for Example II.A-1A. The central problem statement is to verify the available strength of an all-bolted double clip angle beam to column flange shear connection. This connection involves an ASTM A992 W36×231 beam and an ASTM A992 W14×90 column flange supporting beam end reactions of RD = 37.5 kips and RL = 113 kips, using ASTM A572 Grade 50 angles. The connection is shown in Figure 1 and Figure 2.


Figure 1. Example II.A-1A elevation view



Figure 2. Example II.A-1A section A

Connection design report output from SDS2 for this connection:

Note: To view the 3D model (U3D) of the structural joint in the PDF files, open the PDF using Bluebeam or Adobe Acrobat Reader.

Validation Method

The connection as shown in the AISC design example II.A-1A (see reference 1) was modeled in SDS2 and a connection design report was generated for both the ASD and LRFD design methods. It should be noted that due to the star note in AISC Design Examples Fig. II.A-1A-1, the bolt gage on the column flange was set to 7 7/8 so that the edge distance on the bolts would match what was used in the AISC example.

The core of this report features a comparison table for each connection limit state, showcasing the calculated capacities from both SDS2 and AISC. The order of the limit state table generally mirrors the sequence in which it was presented in the AISC example problem. This table also highlights the percent difference (% Δ) between these calculated values, providing a clear measure of any discrepancy, if any.

To further enhance understanding, this report includes relevant notes that discuss any differences or assumptions made during the calculation process. The goal of this comparative study is to evaluate the precision and efficiency of the SDS2 connection design software in contrast to the AISC Design Examples and serves as a guide for better understanding and application of these two design calculations.

Comparison

Comparisons of the limit state checks are presented in Table 1 for ASD and Table 2 for LRFD. The limit state checks and calculated values aligned well between the published AISC Design Example document and the calculation generated by SDS2. The minor differences in calculated values, except where noted, were a result of rounding differences.

Table 1. Capacity comparison table for ASD 

Limit state (ASD)

SDS2 Capacity

AISC Capacity

% Δ

Notes

Shear yielding of angles

294 kips

294 kips

0.0%

 

Shear rupture of angles

201 kips

201 kips

0.0%

 

Block shear rupture of web angle leg

210.6 kips

210 kips

0.3%

 

Block shear rupture of OSL angle leg

211.8 kips

-

-

1

Bolt shear of web bolts

11.9 kips / bolt

11.9 kips / bolt

0.0%

 

Bolt shear of OSL bolts

11.9 kips / bolt

11.9 kips / bolt

0.0%

 

Bolt bearing on angle

18.3 kips / bolt

18.3 kips / bolt

0.0%

 

Bolt tearout of angle at edge bolt

10.3 kips / bolt

10.3 kips / bolt

0.0%

 

Bolt tearout of angle at non-edge bolt

26.7 kips / bolt

26.7 kips / bolt

0.0%

 

Bolt bearing on beam web

44.5 kips / bolt

44.5 kips / bolt

0.0%

 

Bolt tearout of beam web at non-edge bolt

64.8 kips / bolt

65.0 kips / bolt

-0.3%

 

Bolt bearing on column flange

41.5 kips / bolt

41.6 kips / bolt

-0.2%

 

Bolt tearout of column flange at non-edge bolt

60.6 kips / bolt

60.5 kips / bolt

0.2%

 

Bolt group shear at web and OSL bolts

190.9 kips

-

-

2

Bolt group bearing on OSL

187.6 kips

-

-

2

Bolt group bearing on web leg

187.6 kips

-

-

2

Bolt group bearing on beam web

190.9 kips

-

-

2

Bolt group bearing on supporting member

190.9 kips

-

-

2

Shear transfer at web bolts

187.6 kips

187 kips

0.3%

 

Shear transfer at column bolts

187.6 kips

187 kips

0.3%

 

Shear yielding of beam web

554.8 kips

-

-

3

Connection capacity

187.6 kips

187 kips

0.3%

 


Table 2. Capacity comparison table for LRFD

Limit state (LRFD)

SDS2 Capacity

AISC Capacity

Notes

Shear yielding of angles

441 kips

441 kips

0.0%

 

Shear rupture of angles

302 kips

302 kips

0.0%

 

Block shear rupture of web angle leg

315.9 kips

315 kips

0.3%

 

Block shear rupture of OSL angle leg

317.8 kips

-

-

1

Bolt shear of web bolts

17.9 kips / bolt

17.9 kips / bolt

0.0%

 

Bolt shear of OSL bolts

17.9 kips / bolt

17.9 kips / bolt

0.0%

 

Bolt bearing on angle

27.5 kips / bolt

27.5 kips / bolt

0.0%

 

Bolt tearout of angle at edge bolt

15.5 kips / bolt

15.5 kips / bolt

0.0%

 

Bolt tearout of angle at non-edge bolt

40.1 kips / bolt

40.1 kips / bolt

0.0%

 

Bolt bearing on beam web

66.7 kips / bolt

66.7 kips / bolt

0.0%

 

Bolt tearout of beam web at non-edge bolt

97.3 kips / bolt

97.5 kips / bolt

-0.2%

 

Bolt bearing on column flange

62.3 kips / bolt

62.3 kips / bolt

0.0%

 

Bolt tearout of column flange at non-edge bolt

90.9 kips / bolt

90.8 kips / bolt

0.1%

 

Bolt group shear at web and OSL bolts

286.3 kips

-

-

2

Bolt group bearing on OSL

281.4 kips

-

-

2

Bolt group bearing on web leg

281.4 kips

-

-

2

Bolt group bearing on beam web

286.3 kips

-

-

2

Bolt group bearing on supporting member

286.3 kips

-

-

2

Shear transfer at web bolts

281.4 kips

282 kips

-0.2%

 

Shear transfer at column bolts

281.4 kips

282 kips

-0.2%

 

Shear yielding of beam web

832.2 kips

-

-

3

Connection capacity

281.4 kips

282 kips

-0.2%

 

Table Notes

Note 1: AISC only checks the smaller edge distance case that occurs at web leg.

Note 2: AISC does not calculate this individual limit state per bolt group.

Note 3: Not checked by AISC.

References

  1. AISC Committee on Manuals, Companion to the AISC Steel Construction Manual Volume 1: Design Examples, Version 16.0, American Institute of Steel Construction, 2023, https://www.aisc.org/publications/steel-construction-manual-resources/16th-ed-steel-construction-manual/manual-companion-for-16th-edition/.