The Web Penetration with Stiffeners custom component

  • Click here for help documentation on the Web Penetration with Stiffeners custom component from the SDS2 Detailing help manual.
  • You cannot add or modify a custom component in SDS2 Site Planning. You can review component settings.
VIDEO A void space with stiffeners is added to a beam web in a full-featured SDS2 program. Then the component is moved by right clicking and choosing " Move Component ." (Recorded in SDS2 Detailing , v2017.)
Layout 1 is an opening without stiffeners.

Layout 2 is horizontal stiffeners above and below the opening.

Layout 3 is full-depth vertical stiffeners to the left and right of the opening.

Layout 4 is partial-depth vertical stiffeners to the left and right of the opening along with horizontal stiffeners above and below the opening.

Layout 5 is full-depth vertical stiffeners to the left and right of the opening along with horizontal stiffeners above and below the opening.

page 1 | contents | component (beam)