" Gusset 2 Point " connection design locks

NS and FS shared gusset plates field bolt to the left and right flanges of web-horizontal wide flange vertical braces and are designed per " Gusset 2 Point " locks when ' Flange gussets ' is the selected " Connection arrangement ." The near-side flange gusset is shown in this example. The two gusset plates shop attach to the column per choices made to " Weld Conn2 " or " NS/FS Clip Conn2 " locks.

(web-horizontal W vertical braces, shared flange gussets, to a column)
(vertical brace " Section size " = wide flange, S shape or welded plate wide flange)
(" Input connection type " = ' Vbrc Plate ' or ' User defined ')
(" Web orientation " = ' Horizontal ')
(" Connection arrangement " = ' Flange gussets ')
" Gusset 2 Point "
(gusset plate dimensions and location)

" Brace Connection To Gusset Wide Flange Flange Plate "
(field bolting the brace flanges to the gussets)

" Weld Conn2 "
(" Gusset to supporting member " = ' Welded ')

The NS & FS flange gusset plates shop weld or shop bolt to the column based on the choice made to " Gusset to supporting member " under " Connection specifications " section on the Vertical Brace Edit window. That choice also sets whether you get " Weld Conn2 " locks or " NS/FS Clip Conn2 " locks for a 2-point gusset. A 3-point gusset must shop weld to the column, and you will therefore always get " Weld Conn2 " locks for a 3-point gusset.


Related locks :
NS/FS Clip Conn2

The connection design locks for 2-point bracing (2 braces to a shared gusset) and 3-point bracing are essentially the same. However, you cannot connect a 3-point gusset plate to the supporting column with a clip angle (" NS/FS Clip Conn2 ") . A 3-point gusset plate must be welded to the supporting column (" Weld Conn2 ").

User Defined Connections: Settings that are locked ( ) in the user defined connection file will automatically be locked on the member edit window. You can, if you so choose, manually lock additional settings on the member edit window, and your changes will be retained, through multiple processes, so long as you do not change to a different connection then switch back to the original user defined connection.

Vertical Brace Edit: To change a setting, first set it to locked ( ). Related settings that are unlocked ( ) may be updated, and the " Left/Right end limit state " calculations will be updated. Settings that are locked ( ) will not be changed by connection design , even if doing so might prevent a connection failure.

user defined | vertical brace edit | top


Connection design locks :

Locks not dimensioned or called out on the drawing are marked ( not depicted ).

  Gusset 2 Point
( web-horizontal wide flange vertical braces, flange gussets, to a column )

Shared gusset plate dimensions and location

Plate thickness ( not depicted ): The " Material thickness " of the near-side flange gusset. This also sets the thickness for the far-side flange gusset.

Width ( plate width ): The distance (perpendicular to the work line of the supporting column) from the framing edge of the gusset plate (which welds to the column in the example shown) to the opposite edge of the gusset plate (which is parallel with the framing edge of the gusset plate). If the column is perfectly vertical, the flange gusset " Width " can also be defined as the horizontal distance between the two vertical edges of the plate.

Length ( plate length ): The length of the framing edge of the gusset plate (which welds to the supporting column in the example shown). Flange gusset " Length " is measured parallel with the work line of the supporting column. Since the framing edge of the gusset plate is parallel with the column, the flange gusset " Length " is parallel with the work line of the column. If the column is vertical, the flange gusset " Length " can also be defined as the vertical distance between the two horizontal edges of the gusset plate.

Refy: The positive (+) or negative (-) distance (perpendicular to the supporting column's work line ) from the work point of the vertical brace to the framing edge of the gusset plate (which welds to the column's flange in the example shown). If the column is vertical, this distance is horizontal. Changing the " Refy " moves the gusset plate perpendicular to the work line of the column (horizontally if the column is vertical), but does not move the holes on the plate.

Left Brace [ member number ]

Refx ( refx left ): The positive (+) or negative (-) distance (parallel with the supporting column's work line ) from the work point of the left vertical brace to the corner of the framing edge of the gusset plate that is closest to the left end of the column (see example ). For a shared gusset plate to a perfectly vertical column, this distance is vertical. Changing the " Refx " moves the gusset plate parallel with the work line of the column, but does not move the holes on the plate. Hole positioning is governed by the " Brace Connection To Gusset Wide Flange Flange Plate " connection design locks.

Connection cut width ( cut width ): The distance (perpendicular to the work line of the supporting column) between the two corners of the left connection edge of the shared gusset plate. The left connection edge is the edge that the left vertical brace frames to (see example ). This distance is not the actual length of the edge, but the length of that edge as measured parallel with the depth of the column.

Connection cut length ( cut length ): The distance (parallel with the work line of the supporting column) between the two corners of the left connection edge of the shared gusset plate. The left connection edge is the edge that the left vertical brace frames to (see example ). This distance is not the actual length of the edge, but the length of that edge as measured parallel with the work line of the column.

Right Brace [ member number ]

Refx ( refx right ): The positive (+) or negative (-) distance (parallel with the supporting column's work line ) from the work point of the right vertical brace to the corner of the gusset plate's framing edge that is closest to the right end of the column. This works similar to the way that " Refx " works for the left vertical brace.

Connection cut width ( cut width ): Same as " Connection cut width " for the left brace, except that this applies to the right brace.

Connection cut length ( cut length ): Same as " Connection cut length " for the left brace, except that this applies to the right brace.

user defined | vertical brace edit | top


  Brace Connection To Gusset Wide Flange Flange Plate
( web-horizontal wide flange vertical braces, 2- or 3-point, flange gussets, to a column )

Hole pattern for field bolting the braces to the flange gussets

Hole type ( not depicted ): Standard round or Short slot or Oversized or Long slot or User slot #1 or User slot #2 . The hole type selected here, together with the " Bolt diameter " entered below, set the diameter of holes for field bolting the web-horizontal wide flange brace to the near-side and far-side flange gussets.

Bolt diameter ( not depicted ): You can either type in any diameter (inches or mm), or you can select a bolt diameter from the combo box ( ). The diameters that are listed in the combo box come from Home > Project Settings > Job > Bolt Settings > the " Available bolt diameters " list. The bolt diameter entered here, together with the " Hole type " entered above, set the diameter of holes through the near-side and far-side flange gussets.

Rows: The total number of holes in any column of holes on the near-side flange gusset. The number of " Rows " entered here is also applied to the far-side flange gusset (see example ). Bolt row spacing on a web-horizontal wide flange brace flange gusset runs parallel with the work line of the vertical brace. For the brace shown in the example above, the number of " Rows " is ' 3 '.

Distance to 1st hole along brace ( to 1st hole ): The distance (parallel with the work line of the vertical brace) from the work point for this end of the vertical brace to the center of the nearest row of holes on the flange gusset (see example ).

Hole spacing along brace ( rsp ): Row spacing. This is the distance (center to center) between of any two adjacent holes in the same column of holes on the flange gusset (see example ). This distance is measured parallel with the work line of the vertical brace.

End connection failure message: Invalid bolt spacing

Edge distance along brace ( ed ): The distance from the forward edge of the web-horizontal wide flange vertical brace's flange to the nearest hole in that brace's flange. See the example . The forward edge of the brace's flange is the edge that is closest to the work point of the vertical brace. Holes in the brace's flange are for field bolting to the flange gusset plates. This edge distance applies to both flanges of the brace.

Other edge distance along brace ( other ed ): The distance from the connection edge of the flange gusset plate to the nearest hole for field bolting that flange gusset plate to the flange of the web-horizontal wide flange vertical brace. See the example . This one edge distance applies to both flange gusset plates.

Columns: The number of columns of holes on the flange gusset (see example ). These holes are used for field bolting the flange of the brace to the gusset. Column spacing runs perpendicular to the work line of the web-horizontal wide flange brace. In the example above, the number of " Columns " is ' 2 '.

Distance to 1st hole perpendicular to brace ( perp ): The distance from the work line of the vertical brace perpendicular to the nearest column of holes. In the example above, this distance would be half the " Hole spacing perpendicular to brace " since the work line of the brace is centered between the two columns of holes.

Hole spacing perpendicular to brace ( csp ): Column spacing. This is the distance (center to center) between any two columns of holes (see example ). Bolt column spacing runs perpendicular to the work line of the web-horizontal wide flange brace.

user defined | vertical brace edit | top


  Weld Conn2
( web-horizontal wide flange vertical braces, 2- or 3-point, flange gussets, to a column )

Shop weld, shared gusset plate to the supporting column

Weld size ( weld ): The weld size for shop welding each of the two flange gusset plates to the supporting column. See the example . Flange gussets for 2-point bracing can optionally be shop-bolted to the column with a clip angle (" NS/FS Clip Conn2 "). The flange gussets are detailed with the supporting column and field bolt to the web-horizontal wide flange braces.

To get a weld (" Weld Conn2 "), select ' Welded ' for " Gusset to supporting member " under " Connection specifications " on the Vertical Brace Edit window.

To instead get a clip angle (" NS/FS Clip Conn2 "), select ' Clip Angle ' for " Gusset to supporting member ."

A special case : If the supporting column has a narrow flange and ' Welded ' is selected for " Gusset to supporting member ," the flange gussets may shop weld to the supporting column's flange with clip angles.

user defined | vertical brace edit | top