" Brace Connection To Gusset Wide Flange Flange Angle " connection design locks

Flange angles for field bolting a wide flange vertical brace to a column & base plate (shown) or column & cap plate (not shown) are designed per " Brace Connection To Gusset Wide Flange Flange Angle " locks when the " Connection arrangement " is ' Standard ' and the " Flange connection type " is ' Claw angles '. The locks control all four angles simultaneously.

(W vertical brace, flange angles field bolted to gusset, to a column & base/cap plate)
(vertical brace " Section size " = wide flange, S shape or welded plate wide flange)
(" Input connection type " = ' Vbrc Plate ' or ' User defined ')
(" Web orientation " = ' Vertical ')
(" Connection arrangement " = ' Standard ')
(" Flange connection type " = ' Claw angles ')

" Brace Conn To Gusset Wflg Flange Angle "
( angle to brace connection ) ( shop bolted )

" Brace Conn To Gusset Wflg Flange Angle "
( angle to gusset connection ) ( field bolted )

Related locks : Brace Connection To Gusset Wide Flange Web Plate
Gusset Column Cap
Weld Conn1 and Weld Conn2
Cap Plate (if auto base/cap plate)

User Defined Connections: Settings that are locked ( ) in the user defined connection file will automatically be locked on the member edit window. You can, if you so choose, manually lock additional settings on the member edit window, and your changes will be retained, through multiple processes, so long as you do not change to a different connection then switch back to the original user defined connection.

Vertical Brace Edit: To change a setting, first set it to locked ( ). Related settings that are unlocked ( ) may be updated, and the " Left/Right end limit state " calculations will be updated. Settings that are locked ( ) will not be changed by connection design , even if doing so might prevent a connection failure.

user defined | vertical brace edit | top


Connection design locks :

Locks not dimensioned or called out on the drawing are marked ( not depicted ).

  Brace Connection To Gusset Wide Flange Flange Angle
( wide flange vertical brace, standard connection, to a column & base/cap plate )

Flange angle dimensions and location

Section size ( not depicted ): The section size of the four flange angles used to bolt the gusset plate to the wide flange vertical brace. For example, L4x3x5/16. The angle you enter here must exist in the local shape file, or validation will not accept your entry. To enter an angle section size, you can type in the section size, or you can press the "file cabinet" browse button ( ) and double-click a section size from the list of available angles in the local shape file .

Long leg to ( not depicted ): Supporting or Supported . ' Supporting ' field bolts the long leg of the angle to the gusset plate. ' Supported ' shop bolts the long leg of the angle to the flange of the wide flange vertical brace.

Length ( L length ): The distance (parallel with the work line of the vertical brace) from the edge of the angle that is closest to the work point for this end of the vertical brace to the edge of the angle that is closest to the work point for the opposite end of the vertical brace (see example ). This distance is the length that you want the selected " Section size " to be cut to. Assuming that this field is unlocked, changing the number of " Rows " will cause the " Length " of the angle to be automatically recalculated.

Refx ( angle refx ): The distance (parallel with the work line of the vertical brace) from the work point for this end of the vertical brace to the nearest edge of any one of the flange angles (see example ). This distance applies to all four of the flange angles.

Refy: The distance (parallel with the work line of the vertical brace) from the work point for this end of the vertical brace to the heel of any one of the flange angles (see example ). This distance applies to all four of the flange angles. See the example .

Gage leg ( not depicted ): The distance (perpendicular to the work line of the vertical brace) from the heel of any one of the angles to the center of the column of holes for shop bolting that angle to the flange of the vertical brace. This gage applies to all four of the flange angles.

Gage osl ( gage ): The distance (perpendicular to the work line of the vertical brace) from the heel of any one of the angles to the center of the column of holes for field bolting that angle to the gusset plate -- see example ). This gage applies to the outstanding legs of all four of the flange angles.

Angle to gusset connection ( field bolted )

Bolt diameter ( not depicted ): You can either type in any diameter (inches or mm), or you can select a bolt diameter from the combo box ( ). The diameters that are listed in the combo box come from Home > Project Settings > Job > Bolt Settings > the " Available bolt diameters " list. The bolt diameter entered here together with the " Hole type " entered below set the diameter of holes through the leg of the angle that field bolts to the gusset plate.

Hole type ( not depicted ): Standard round or Short slot or Oversized or Long slot or User slot #1 or User slot #2 . The hole type selected here, together with the " Bolt diameter " entered above, set the diameter of holes through the leg of the angle that field bolts to the gusset plate.

Rows: The number of bolts that fasten an angle to the gusset plate. For the example shown, this number is ' 2 '.

Distance to 1st hole along brace ( to first gus hole ): The distance (parallel with the work line of the vertical brace) from the work point for this end of the vertical brace to the center of the nearest hole on the flange angle (see example ).

Hole spacing along brace ( sp ): Row spacing. This is the distance (center to center) between adjacent holes used for bolting an angle to the gusset plate (see example ).

End connection failure message: Invalid bolt spacing

Edge distance along brace ( edge dist ): The distance from the forward edge of the angle to the nearest hole in the leg that bolts to the gusset plate (see example ). The forward edge is the edge of the angle that is closest to the work point of the brace.

Other edge distance along brace ( other ed ): The distance from the edge of the gusset plate to the nearest hole for bolting the angle to the gusset plate (see example ).

Angle to brace connection ( shop bolted )

Bolt diameter ( not depicted ): You can either type in any diameter (inches or mm), or you can select a bolt diameter from the combo box ( ). The diameters that are listed in the combo box come from Home > Project Settings > Job > Bolt Settings > the " Available bolt diameters " list. The bolt diameter entered here together with the " Hole type " entered below determine the diameter of holes through the leg of the angle that shop bolts to the flange of the wide flange vertical brace.

Hole type ( not depicted ): Standard round or Short slot or Oversized or Long slot or User slot #1 or User slot #2 . The hole type selected here, together with the " Bolt diameter " entered above, determine the diameter of holes through the leg of the angle that shop bolts to the flange of the wide flange vertical brace.

Rows: The number bolts that fasten an angle to the flange of the wide flange vertical brace. For the example shown, this number is ' 2 '. Assuming that the angle " Length " is not locked, then changing the number of " Rows " will cause the length of the angle to also change.

Distance to 1st hole along brace ( to first brc hole ): The distance (parallel with the work line of the vertical brace) from the work point for this end of the vertical brace to the center of the nearest hole on the flange of the wide flange vertical brace (see example ). Changing the " Distance to 1st hole along brace " moves the holes on the leg of the angle, but does not change the length of the angle.

Hole spacing along brace ( rs ): Row spacing. This is the distance (center to center) between adjacent holes used for bolting the angle to the flange of the wide flange or S shape or welded plate wide flange vertical brace (see example ).

End connection failure message: Invalid bolt spacing

Edge distance along brace ( ed ): This applies to the angle leg that bolts to the flange of the vertical brace. It is the distance from the edge of that leg to the nearest hole on that leg. See the example .

Other edge distance along brace ( oed ): The distance from the edge of the brace's flange to the nearest hole for bolting the angle to the flange. See the example .

user defined | vertical brace edit | top