Field Bolts For Members by Zone
Tool summary :
Also see :
- Field bolts ( Bolt Edit window > " Bolt class " )
- Field bolts listed on which members ( Fabricator > Detailing > Bolt Detailing Settings > )
- Dividing a Model into Sequences/Zones (topic)
- Bolt designation shown in reports ( Fabricator > Detailing > Bolt Detailing Settings > )
- Zone Names ( Job > Modeling > Zone and Sequence > press " Zone Names " > )
- Reports ( User and Site Options > Output > " Reports " > set report output)
- Report viewer (a good way to output a report)
page 1 | contents | home > reports > system reports > | reports > field bolts > | top
Columns on the report :
Report writer links are based on the data source fields for the Report Writer's Field Bolts For Members By Zone , which you can Open in the reports/SDS2 folder. |
Zone: The zone that the field bolts listed in the following columns are in.
Report Writer: Member.ErectionZone
Line: The number of the line assigned to this group of field bolts . Each group of field bolts in a line is the same length and diameter and is associated with a distinct piecemark.
Piecemark: The piecemark ( member piecemark ) of the members in this zone fastened by this group of field bolts at the construction site (the zone is listed at the top of each page of this report). If ' Supported ' is selected for " Field bolts listed on which members ," then field bolts are listed for the supported members that were added (or for some other reason underwent Process and Create Solids ) since ' Supported ' was selected. If ' Supporting ' is selected, supporting members are listed.
Report Writer: Member.Piecemark
Count: The total number of field bolts on all members in this zone that share the particular piecemark reported on this line. In other words, this is the total quantity of field bolts needed to erect all members in this zone that share this piecemark. If, for instance, three members in this zone share the same piecemark, and each of these members has four field bolts, the reported count is 12.
Diameter: The diameter of each bolt in the group of field bolts reported on this line.
diameter |
Report Writer: MemberMaterial.Bolt.DiameterDimension
Type: The material grade of each of the field bolts specified on this line. This column also includes the bolt type if ' Bolt material & type ' is selected for the setup option " Bolt designation shown in reports ."
Report Writer: MemberMaterial.Bolt.BoltTypeDescription
Length: The distance from the inside of the bolt head to the end of the shaft. The program does not include the head thickness in its calculation of bolt length because head thickness may vary among bolt manufacturers.
length |
Report Writer: MemberMaterial.Bolt.LengthDimension
Head Washer: The number of washers under the head of the field bolt and their type ( HD or PL or RPL or FL or BVL or DTI or HLS ). If this cell is left blank, then there is no washer under the head of the field bolt.
washer under head |
hardened
(HD) |
square
plate (PL) |
round
plate (RPL) |
flat
(FL) |
bevel
(BVL) |
load
(DTI) |
hillside
(HLS) |
Report Writer: MemberMaterial.Bolt.PrimaryHeadWasher.TypeDescription
Report Writer: MemberMaterial.Bolt.SecondaryHeadWasher.TypeDescription
Nut Washer: The number of washers under the nut of the field bolt and their type ( HD or PL or RPL or FL or BVL or DTI or HLS ). If this cell is left blank, then there is no washer under the nut of the field bolt.
washer under nut |
hardened
(HD) |
square
plate (PL) |
round
plate (RPL) |
flat
(FL) |
bevel
(BVL) |
load
(DTI) |
hillside
(HLS) |
Report Writer: MemberMaterial.Nut.PrimaryNutWasher.TypeDescription
Report Writer: MemberMaterial.Nut.SecondaryNutWasher.TypeDescription
TC: Yes or No . If the bolts on this line are TC (Tension Control) bolts, this cell reads ' Yes '. If the bolts are not TC bolts, the cell reads ' No '.
Report Writer: MemberMaterial.Bolt.IsTensionControl
page 1 | contents | home > reports > system reports > | reports > field bolts > | top
How to output a Field Bolts For Members by Zone :
Generally field bolts are shipped loose to the construction site. A Field Bolts for Members by Zone report is specifically designed for situations where members are shipped to or erected at a job site by zone.
1 . Before output of this report:
1a : This report is compiled from the 3D model. When you Process & Create Solids , you effectively update the model for your current Job . You can then output a Field Bolts For Members by Zone that will be up to date.
1b (optional) : If you want only the steel grade to be listed in this report for the column " Type ," then set the setup option " Bolt designation shown in reports " to ' Bolt material only '.
Warning: If you change Home > Project Settings > Fabricator > Bolt Detailing Settings > " Field bolts listed on which members ," you must Process and Create Solids all members in your current Job if you want this report to be fully up to date.
2 . Use any one (1) of the following methods to begin output of this report:
Method 1 : Home > Reports > System Reports > Field Bolts > Field Bolts For Members by Zone .
Method 2 : Click the Field Bolts For Members by Zone icon, which is pictured above. The icon can be taken from the group named ' Reports ' and placed on a toolbar (classic) or the ribbon (lightning). Ribbon configuration is done using Customize Interface .
Method 3 : If " Modeling layout style " or " Drawing Editor layout style " is ' Classic ', you can use the menu system to choose Reports > Field Bolts > Field Bolts For Members by Zone.
3 . The Output Configuration window opens, allowing you to change where you " Send output to " (for example, to " File " or " Screen " or " Printer ").
Alternative 1 : Press " OK " to output the report. Go to step 4.
Alternative 2 : Press " Cancel " to end this operation without generating the report. Do not continue.
4 . The Field Bolts For Members by Zone report is output to the device/ location that you designated.
Note: If you output to the report viewer (" Screen "), you can now review the report on screen, then optionally print it or output it to disk (see report viewer ).
page 1 | contents | home > reports > system reports > | reports > field bolts > | top